Home  >  PRODUCTS  >  Road Lighting  >  Non-isolation driver-LNC series  > 

200W Non-isolated LED driver

这里可以自定义设置
200W Non-isolated LED driver

Product Name: 200W Non-isolated LED driver
Product Model: LNC-200B232
Product Code: MS003877-V0

Add success, do you want to check your shopping cart?

暂无分享


SPECIFICATION

DOWNLOAD

OPERATING AREA

CERTIFICATE

MECHANICAL OUTLINE

这里可以自定义设置

1. Scope

This document defines the electrical, mechanical and environmental specifications of a 200W Non-isolated LED driver. The LED driver shall meet the RoHS requirement.
This enclosure of LED driver is: With AL Case.

2. Input Characteristics

2.1 Input Voltage and Frequency

Item

Minimum

Rated Value

Maximum

Input Voltage

90Vac

100-277Vac

305Vac

Input Frequency

47Hz

50/60 Hz

63Hz

2.2 AC Input Current
Under 25℃±10℃ ambient temperature, rated input and output range, maximum AC input current is 2.7A.

2.3 Inrush Current ( Cold Start )
Under 25℃±10℃ ambient temperature, 230Vac input, the peak value of the inrush current is less than 75A.

2.4 Power Factor

2.4.1 Under 25℃±10℃ ambient temperature, 115Vac input, 100% load, the typical value of power factor is 0.98 , the minimum value is 0.97(reference Power Factor vs. Load Curve);
2.4.2 Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, the typical value of power factor is 0.96 , the minimum value is 0.95(reference Power Factor vs. Load Curve);
2.4.3 Under 25℃±10℃ ambient temperature, 277Vac input, 100% load, the typical value of power factor is 0.92 , the minimum value is 0.90,(reference Power Factor vs. Load Curve).

2.5 Efficiency
2.5.1 Under 25℃±10℃ ambient temperature, 115Vac input, 190 V output voltage, 100% load, the typical value of efficiency is 92 %, the minimum value is 90 %(reference Efficiency vs. Load Curve);
2.5.2 Under 25℃±10℃ ambient temperature, 230Vac input, 190 V output voltage, 100% load, the typical value of efficiency is 94 %, the minimum value is 92 %(reference Efficiency vs. Load Curve).

2.6 THD
2.6.1 Under 25℃±10℃ ambient temperature, 230Vac input, 80-100% load, THD is less than 15% (reference THD Curve);
2.6.2 Under 25℃±10℃ ambient temperature, 277Vac input, 80-100% load, THD is less than 20% (reference THD Curve).

2.7 Standby power consumption
Under 25℃±10℃ ambient temperature, rating input voltage, the average value of standby power consumption is less than 10W.

这里可以自定义设置

Click the button below to download the PDF file.

这里可以自定义设置

3. Output Characteristic

3.1 Output Power
Under full input voltage range, the maximum value of output power is 130 W.


3.2 Output Voltage and Current

Tem ( Unit )

Value

Test Condition ( Under 25℃±10℃ Ambient Temperature )

Output Current ( A )

0.860

Full input voltage range

Output Voltage Range ( V )

170~232

Full input voltage range

Error of Output Current

±5%

Full input voltage range, full load range(the typical value)

No Load Output Voltage (V)

≤300V

Full input voltage range

Note: the error of output current is less than±8%

3.3 Output Current Ripple
Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, the ratio of output current ripple【 1】 peak-peak value and rated output current is less than 20 %.
Note: load is LED, ripple is different with difference LED load. @ Measurement is done by 20MHz bandwidth oscilloscope.

3.4 Cold Start Turn-On Delay Time
Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, turn-on delay time at cold start is less than 0.5s; 115Vac input, less than 3S.

3.5 Output Current Overshoot
Under 25℃±10℃ ambient temperature, 100-277Vac input, LED full load, the ratio of output current overshoot and rated output current is less than 10 %.

3.6 Line Regulation (Input Voltage Regulation)
Under 25℃±10℃ ambient temperature, 100% load, change input from 100Vac to 277Vac, the Line Regulation (Input Voltage Regulation) is less than 1 %.

3.7 Load Regulation
Under 25℃±10℃ ambient temperature, 100-277Vac input voltage, change load from 80% to 100%, Load Regulation is less than 3 %.

Safety Certification

Country and region

Standards

Whether have Certification

CCC

China

GB19510.1


GB19510.14

CE

Europe

EN61347-1


EN61347-2-13

CB

CB member

IEC61347-1


IEC61347-2-13

UL

America

UL 8750


UL 1310(Class 2 Power Units)


UL 1012


CUL

Canada

CSA C22.2 No.250.13-12


CSA C22.2 No.223-M91(Power Supplies With Extra-Low-Voltage Class 2 Outputs)


AS/NZS 61347.1


KC

Korea

K61347-1


K61347-2-13

K62384

PSE

Japan

J61347-1


J61347-2-13

SAA

Australia

AS/NZS IEC 61347-2-13


AS/NZS 61347.1

这里可以自定义设置

EMC Certification

Country and region

Standards

Whether have Certification

CCC

China

GB 17743


GB 17625.1

CE

Europe

EN 55015


EN 61000-3-2

EN 61000-3-3

EN 61547

KC

Korea

K61547


K00015

PSE

Japan

J55015


FCC

America

FCC part 15


这里可以自定义设置

10.1.2 Relative Humidity: 20% to 95%, non-condensing.

10.2 Storage Temperature and Humidity
10.2.1 Temperature: -40℃ to +85℃;
10.2.2 Relative Humidity: 20% to 95%, non-condensing.

10.3 Degrees of Protection

这里可以自定义设置

Wire

Specification

AC Input

CCC+VDE  3x1.0mm2  L=400mm

DC Output

CCC+VDE  2x1.0mmL=300mm

Product Message

Submit successfully
We will review as soon as possible
Chat Online 编辑模式下无法使用
Chat Online inputting...
Dear friend,thanks for your inquiry. Please leave your company E-mail and phone number, we will contact you asap. Have a good day!Contact E-mail:Niki.li@mosopower.com TEl: +86-755-27657000