1. Scope

This document defines the electrical, mechanical and environmental specifications of a 150W Non-isolated LED driver. The LED driver shall meet the RoHS requirement.
This enclosure of LED driver is: With AL Case.

2. Input Characteristics

2.1 Input Voltage and Frequency

Item

Minimum

Rated Value

Maximum

Input Voltage

90Vac

100-277Vac

305Vac

Input Frequency

47Hz

50/60 Hz

63Hz

2.2 AC Input Current
Under 25℃±10℃ ambient temperature, rated input and output range, maximum AC input current is 2.3A.

2.3 Inrush Current ( Cold Start )
Under 25℃±10℃ ambient temperature, 230Vac input, the peak value of the inrush current is less than 75A.

2.4 Power Factor
2.4.1 Under 25℃±10℃ ambient temperature, 115Vac input, 100% load, the typical value of power factor is 0.98 , the minimum value is 0.97(reference Power Factor vs. Load Curve);
2.4.2 Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, the typical value of power factor is 0.96 , the minimum value is 0.95(reference Power Factor vs. Load Curve);
2.4.3 Under 25℃±10℃ ambient temperature, 277Vac input, 100% load, the typical value of power factor is 0.92 , the minimum value is 0.90,(reference Power Factor vs. Load Curve).

2.5 Efficiency
2.5.1 Under 25℃±10℃ ambient temperature, 115Vac input, 190 V output voltage, 100% load, the typical value of efficiency is 92 %, the minimum value is 90 %(reference Efficiency vs. Load Curve);
2.5.2 Under 25℃±10℃ ambient temperature, 230Vac input, 190 V output voltage, 100% load, the typical value of efficiency is 94 %, the minimum value is 92 %(reference Efficiency vs. Load Curve).

2.6 THD
2.6.1 Under 25℃±10℃ ambient temperature, 230Vac input, 80-100% load, THD is less than 15% (reference THD Curve);
2.6.2 Under 25℃±10℃ ambient temperature, 277Vac input, 80-100% load, THD is less than 20% (reference THD Curve). 

2.7 Standby power consumption
Under 25℃±10℃ ambient temperature, rating input voltage, the average value of standby power consumption is less than 10W.

这里可以自定义设置

Click the button below to download the PDF file.

这里可以自定义设置

3. Output Characteristic

3.1 Output Power
Under full input voltage range, the maximum value of output power is 130 W.


3.2 Output Voltage and Current

Item ( Unit )

Value

Test Condition  ( Under 25℃±10℃ Ambient Temperature )

Output Current ( A )

0.830

Full input voltage range

Output Voltage Range( V )

130~190

Full input voltage range

Error of Output Current

±5%

Full input voltage range, full load range(the typical value)

No Load Output Voltage( V)

≤250V

Full input voltage range

Note: the error of output current is less than±8%

3.3 Output Current Ripple
Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, the ratio of output current ripple【 1】 peak-peak value and rated output current is less than 20 %.
Note: load is LED, ripple is different with difference LED load. @ Measurement is done by 20MHz bandwidth oscilloscope.

3.4 Cold Start Turn-On Delay Time
Under 25℃±10℃ ambient temperature, 230Vac input, 100% load, turn-on delay time at cold start is less than 0.5s; 115Vac input, less than 3S.

3.5 Output Current Overshoot
Under 25℃±10℃ ambient temperature, 100-277Vac input, LED full load, the ratio of output current overshoot and rated output current is less than 10 %.

3.6 Line Regulation (Input Voltage Regulation)
Under 25℃±10℃ ambient temperature, 100% load, change input from 100Vac to 277Vac, the Line Regulation (Input Voltage Regulation) is less than 1 %.

3.7 Load Regulation
Under 25℃±10℃ ambient temperature, 100-277Vac input voltage, change load from 80% to 100%, Load Regulation is less than 3 %.

4. Protect Function

4.1 Short Circuit Protection
The average value of input power shall less than 10W when the output rail short, the power supply shall be self-recovery when the fault condition is removed.
4.2 Over Voltage Protection
When the output voltage is 1.05-1.3 Rated Load Voltage, the driver enters protection status, the driver will work normally after fault condition removed.

8. Safety and Electromagnetic Compatibility

8.1 Safety Standards

Safety Certification

Country and region

Standards

Whether have Certification

CCC

China

GB19510.1

 

GB19510.14

 

CE

Europe

EN61347-1

 

EN61347-2-13

 

CB

CB member

IEC61347-1

 

IEC61347-2-13

 

UL

America

UL 8750

 

UL 1310( Class 2 Power Units)

 

UL 1012

 

cUL

Canada

CSA C22.2 No.250.13-12

 

CSA C22.2 No.223-M91 ( Power Supplies
With Extra-Low-Voltage Class 2 Outputs)

 

AS/NZS 61347.1

 

KC

Korea

K61347-1

 

K61347-2-13

 

K62384

 

PSE

Japan

J61347-1

 

J61347-2-13

 

SAA

Australia

AS/NZS IEC 61347-2-13

 

AS/NZS 61347.1


这里可以自定义设置

8.2 Electromagnetic Compatibility Standards

EMC Certification

Country and region

Standards

Whether have Certification

CCC

China

GB 17743


GB 17625.1

CE

Europe

EN 55015


EN 61000-3-2

EN 61000-3-3

EN 61547

KC

Korea

K61547


K00015

PSE

Japan

J55015


FCC

America

FCC part 15


9. Details Of Safety Specifications

9.1 Dielectric Strength
9.1.1 input to PE : 1650Vac, 60s, current is less than 10mA;
Note: 25±10ambient temperature, I/P: L, N Line; PE: Protecting Earthing.


9.2 Grounding Resistance
Under 25±10ambient temperature, pass 25A current for 60s, the measured grounding resistance is less than 0.1Ω.


9.3 Leakage Current
Leakage Current is defined as the current flowing through the ground wire. Under 25±10ambient temperature and 240Vac/50Hz input, the leakage current shall be less than 0.70mA.


9.4 Insulation Resistance
Under 25±10ambient temperature and less than 70% relative humidity, apply 500V dc voltage to each port of input to GND last 60s, the insulation resistance at least 50MΩ.


9.5 Surge Immunity Test
Under 25±10ambient temperature, L line to N line is 1000V; L line to earth is2000V; N line to earth is2000V.

10. Environmental Specifications

10.1 Operated Temperature and Humidity
10.1.1 Temperature: -40to +60(reference curve);

这里可以自定义设置

Load VS Ambient Temperature Curve

Load VS Case Temperature Curve

10.1.2 Relative Humidity: 20% to 95%, non-condensing.

10.2 Storage Temperature and Humidity
10.2.1 Temperature: -40℃ to +85℃;
10.2.2 Relative Humidity: 20% to 95%, non-condensing.

10.3 Degrees of Protection

这里可以自定义设置

11. Reliability

11.1 Mean Time Between Failure (MTBF) Qualification (According to MIL-HDBK-217F Standards)
Mean time between failure is at least 200000 hours under 25ambient temperature, 230Vac input, and 80% load.


11.2 Life Time Qualification
The life time is at least 50, 000 hours, under 45case temperature, 230Vac input, and 80% load.


11.3 Vibration
10 to 500HZ Sweep at constant acceleration of 1.0G (depth: 3.5mm) for 1 Hour for each of the perpendicular axes X, Y, Z.


11.4 Drop Test
Ten times 60cm drop test with one angle three edges and six face of complete package, package shall not damage, product function and dielectric strength should meet the requirement.

12. Mechanical Outline

Wire

Specification

AC Input

CCC+VDE 3x1.0mm2 L=400mm

DC Output

CCC+VDE 2x1.0mm2 L=300mm

13. Label